Construction & Building Products Supplier
/
Rubber Gate Seals
/
Center Dome
/
Style 1-Transitional to a Flat Outside Bulb 90 Degree Corner
/
Style 1-Transitional to a Flat Outside Bulb 90-Neoprene 1501
/
S1-TFOB90-N1501-1-3/4″ x 6-1/4″ x 7/16″ x 3/4″ x 1/8″ x 9/16″ x 3/32″ x 18″ x 7/8″ x 3/8″
Categories
Categories
Construction & Building Products Supplier
/
Rubber Gate Seals
/
Center Dome
/
Style 1-Transitional to a Flat Outside Bulb 90 Degree Corner
/
Style 1-Transitional to a Flat Outside Bulb 90-Neoprene 1501
/
S1-TFOB90-N1501-1-3/4″ x 6-1/4″ x 7/16″ x 3/4″ x 1/8″ x 9/16″ x 3/32″ x 18″ x 7/8″ x 3/8″
S1-TFOB90-N1501-1-3/4" x 6-1/4" x 7/16" x 3/4" x 1/8" x 9/16" x 3/32" x 18" x 7/8" x 3/8"
Product Code: S1-TFOB90-N1501-1750-6250-04375-0750-0125-05625-009375-18000-0875-0375
You must be logged in.
Options
Description
Drawing Item Identification:
A: OA height in inches
B: OA width in inches
C: Block width in inches
D: Block height in inches
E: Off set in inches
F: Body thickness in inches
G: Recess in inches
H: Long legs in inches
R1: Dome radius in inches
R2: Radius in inches
NOTE: MATCH “A” DIMENSIONS FOR BOTH PARTS FOR PROPER SEAL ALIGNMENT. USE A 2″ BULB AND TAIL WITH THE 1-15/16″ DOME SEAL.
Solid Bulb and Tail Diagram
A | B | C | R |
---|---|---|---|
1-3/4″ | 7″ | 9/16″ | 5/16″ |
2″ | 7″ | 3/4″ | 1/4″ |
Additional information
(A) OA height in inches | 1-3/4" |
---|---|
(B) OA width in inches | 6-1/4" |
(C) Block width in inches | 7/16" |
(D) Block height in inches | 3/4" |
(E) Off set in inches | 1/8" |
(F) Body thickness in inches | 9/16" |
(G) Recess in inches | 3/32" |
(H) Long legs in inches | 18" |
(R1) Dome radius in inches | 7/8" |
(R2) Radius in inches | 3/8" |
Tensile Strength (Die C ASTM D412) | 2500 psi (min) |
Elongation at Rupture (ASTM D412) | 400% (min) |
300% Modulus (ASTM D412) | – |
Durometer Hardness, Shore Type A (ASTM D2240) | 50 – 60 |
Water Absorption (70 Hrs. @ 212°F ASTM D471) | 10% by volume (max) |
Compression Set (ASTM D395 Method B 22 Hrs/ @ 158°F) | 25% (max) |
Tensile Strength After Oxygen Bomb Aging (ASTM F572) | – |
Low Temperature Brittleness (ASTM D2137 Method A, 9.3.2) | Non-Brittle after 3' @ -40°C |