Does not contain lead, cadmium, mercury or formaldehyde, and meets the global REACH and RoHS requirements covering prohibited substances.

Will meet UL94-HB.

Additional information

Density

Test Method: ASTM D 3575(W), Typical Results: 1.7-2.25 lb/ft3

Tensile Strength

Test Method: ASTM D 3575(T), Typical Results: 40-60 psi

Tear Resistance

Test Method: ASTM D 3575(G), Typical Results: 9-13 lb/in

Elongation

Test Method: ASTM D 3575(T), Typical Results: 260-320 %

Compression Set

Test Method: ASTM D 3575(B), Typical Results: <20 %

Compression Strength 25%

Test Method: ASTM D 3575(D), Typical Results: 7-11 psi

Compression Strength 50%

Test Method: ASTM D 3575(D), Typical Results: 14-20 psi

Thermal Stability

Test Method: ASTM D 3575(S), Typical Results: <3 %

Water Absorption

Test Method: ASTM 1667, Typical Results: 0.128 lbs/sft

Working Temperature

Test Method: RANGE, Typical Results: -40 – 185F